- Disconnect from the 32th floor distributor OUT-terminal to 7th wire(+28V VCC)
in the 33th floor distributor IN-terminal, because the 28rd floor distributor power
supply (28V/5A) will be transmitted to each floor distributors from floors 24 through 31
- Disconnect from the 40th floor distributor OUT-terminal to 7th wire(+28V VCC)
in the 41th floor distributor IN-terminal, because the 36rd floor distributor power
supply (28V/5A) will be transmitted to each floor distributors from floors 32 through 40.
- Disconnect from the 48th floor distributor OUT-terminal to 7th wire(+28V VCC)
in the 49th floor distributor IN-terminal, because the 44rd floor distributor power
supply (28V/5A) will be transmitted to each floor distributors from floors 41 through 48.
- The final 50th floor distributor power supply(28v/5A) cover 49th and 50th
floor distributor.
6
6
6
3. System Diagram and wiring
Wiring the Building distributor(CCU-BS) to Floor distributor
(8 wires : talk 2, Data 2, Video, GND)
Connecting the Floor distributor with the next Floor distributor
(8 wires : talk 2, Data 2, Video, GND)
Each Floor distributor is connectable to up to 4 residences.
Additional Sub-units in each residence are available
(Maximum of 3 units including a Master unit)
Separate power source is needed for additional Sub-units
(Not required for Audio type sub-units)